1-Sinus Penta
5-function, all purpose inverter, up to 3000 kW
Click here for more information »
2-Sinus Penta Box
Inverter in box IP54
Click here for more information »
3-Sinus Penta Cabinet
Inverter in cabinet
Click here for more information »
4-Sinus Penta IP54
Click here for more information »
5-Sinus N
Sensorless vector control or V/F inverter
Click here for more information »
6-Sinus M
Sensorless vector control or V/F inverter
Click here for more information »
7-Sinus K Lift
Vector modulation Lift Software for lift applications
Click here for more information »
DCREG2-DCREG4
AC/DC digital converters, two quadrant DCREG2, four quadrant DCREG4
Click here for more information »
CU400 for Electromagnets
The Thyristor converters DCREG series now offers the possibility to manage highly inductive loads such as electromagnets.
The load’s typology, assimilable to an ohmic resistor placed in series to a very high inductance, creates some applicative problems which have been efficaciously solved inside the DCREG by means of a control algorithm especially developed for this aim. The fact that the load has a high inductance level causes some functional safety problems which show themselves when, for failures or critical installation, an interruption on one of the main supply meshes is possible. Such interruption, along with the high inductive level of the magnet, can provoke strong sudden overvoltage’s which may even reach some thousands of Volts. It is not anyway possible to protect the converter against such overvoltage’s, except if you take specifi c measures while installing it. The most effi cacious method consists in providing a closing mesh on the magnet’s current, thanks to a special system called CU400.
The energy accumulated into the magnet is “absorbed” and stocked into a clamping circuit of RC type, in which the function of overcurrent limiting is ensured by the inner capacitor, while the subsequent dissipation of such energy is ensured by the inner resistor. If a power supply conducting mesh is physically interrupted (because of wiping contacts or other) or the connecting cables between magnet and converter open, the voltage arc generated by the current interruption is limited by the clamping circuit able to limit overvoltage, taking it to safe values. For this reason, the above configuration is necessary in case of electromagnets installed on bridge cranes on which the 3phase power supply comes the main supply by means of wiping brushes which might occasionally open.
Click here for more information »
AMS90/1
Half-controlled AC/DC single-phase drive
Half-controlled AC/DC single-phase drive used to supply armature and field circuits of D.C. motors, with analog circuit for speed or torque control.
Click here for more information »
ASAC0 / ASAC1 Soft starter
Soft start/stop static starters for three-phase asynchronous motors
Click here for more information »
ASoft starterSAB
Soft start/stop static starters for three-phase asynchronous motors
The ASAB is an advanced digital soft start solution for motors from 7 kW to 800 kW. ASAB soft starters provide a complete range of motor and system protection features and have been designed for reliable performance in the most demanding installation situations
Click here for more information »
ASAMV Soft starter
Soft start/stop static starters medium voltage
Click here for more information »